This manuscript proposes to study different cases that require the use of renewable energies in addition to diesel generators and energy storage systems with the aim of increasing the resilience of a microgrid feeding critical facilities. The aim of the work here presented is to quantify the benefits provided by an improvement of the energy resilience that could be achieved by installing a microgrid in a hospital fed by renewable energy sources. The microgrid will use a scheme based on solar PV in addition to diesel generators and an energy storage system based on electrochemical batteries. First, it has been evaluated how the implant of the microgrid increases the resilience of the power supply when a power failure occurs, considering that the main application in a hospital, even in the event of breakdowns, is to ensure the continuity of the surgical procedures and safely store drug stocks. Thus, these has been defined as the critical loads of the system. The components sizes have been optimized by considering both economic profitability but also the resilience capacity, observing that, by installing solar photovoltaic modules, Li-ion batteries and diesel generators, the microgrid could save approximately $440,191 over a 20-year life cycle of the facility (both considering the mitigation of energy provide by the power grid and the avoided losses during probable power services interruptions), while increasing the minimum resilience of the installation more than 34 h.

Resilience Improvement in PreCOVID-19 Medical Centers

Bracco S.;
2024-01-01

Abstract

This manuscript proposes to study different cases that require the use of renewable energies in addition to diesel generators and energy storage systems with the aim of increasing the resilience of a microgrid feeding critical facilities. The aim of the work here presented is to quantify the benefits provided by an improvement of the energy resilience that could be achieved by installing a microgrid in a hospital fed by renewable energy sources. The microgrid will use a scheme based on solar PV in addition to diesel generators and an energy storage system based on electrochemical batteries. First, it has been evaluated how the implant of the microgrid increases the resilience of the power supply when a power failure occurs, considering that the main application in a hospital, even in the event of breakdowns, is to ensure the continuity of the surgical procedures and safely store drug stocks. Thus, these has been defined as the critical loads of the system. The components sizes have been optimized by considering both economic profitability but also the resilience capacity, observing that, by installing solar photovoltaic modules, Li-ion batteries and diesel generators, the microgrid could save approximately $440,191 over a 20-year life cycle of the facility (both considering the mitigation of energy provide by the power grid and the avoided losses during probable power services interruptions), while increasing the minimum resilience of the installation more than 34 h.
2024
9783031677533
9783031677540
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/1237218
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact