INTRODUCTION: Sentinel lymph node biopsy (SLNB) has progressively replaced complete axillary lymph node dissection in the evaluation of breast cancer patients with clinically node-negative disease. Our study investigates the rate of and risk factors involved in sentinel node identification failure. MATERIALS AND METHODS: We collected data on SLNBs performed during 2002-2010, focusing on tumor, patient, and breast characteristics, radioactivity parameters, and operators' experience. Data were analyzed by R (v2.14.2), considering significance at P values lower than 0.05. RESULTS: Among 1050 women who underwent an SLNB, the rate of identification failure was 2% (23/1050), which, on bivariate analysis, was seen to be significantly influenced (P<0.05) by the preoperative and intraoperative low radiotracer uptake (axilla/lesion radiotracer uptake ratio<1%), low level of experience of the specialist in nuclear medicine, luminal A subtype, and radiotracer uptake localization in internal mammary lymph nodes. On multivariate analysis, significant risk factors for sentinel node identification failure were found to be: axilla/lesion radiotracer uptake ratio less than 1%, radiotracer uptake localization in internal mammary lymph nodes, and luminal A subtype. Considering only the preoperative variables in our multivariate analysis, axilla/lesion radiotracer uptake ratio less than 1%, negative lymph node scintiscan, and radiotracer uptake localization in internal mammary lymph nodes had an area under the curve (receiver operating characteristic curve) of 96% (95% confidence interval 92-100%). Further, we built a nomogram based on these simple parameters for counseling the patient about the probability of not finding the sentinel lymph node during the surgical procedure. CONCLUSION: The relatively low prevalence of SLNB failure (2%) is indicative of the accuracy of the procedure when performed by experienced surgeons. The sentinel node identification failure in our population seemed to be related to biological tumor factors (luminal A subtype) and probably to physiological or pathological variations in the lymphatic drainage (axilla/lesion radiotracer uptake ratio<1% and radiotracer uptake localization in internal mammary lymph nodes). © 2013 Wolters Kluwer Health | Lippincott Williams & Wilkins.

Prevalence and risk factors of intraoperative identification failure of sentinel lymph nodes in patients affected by breast cancer

Londero A. P.;
2013-01-01

Abstract

INTRODUCTION: Sentinel lymph node biopsy (SLNB) has progressively replaced complete axillary lymph node dissection in the evaluation of breast cancer patients with clinically node-negative disease. Our study investigates the rate of and risk factors involved in sentinel node identification failure. MATERIALS AND METHODS: We collected data on SLNBs performed during 2002-2010, focusing on tumor, patient, and breast characteristics, radioactivity parameters, and operators' experience. Data were analyzed by R (v2.14.2), considering significance at P values lower than 0.05. RESULTS: Among 1050 women who underwent an SLNB, the rate of identification failure was 2% (23/1050), which, on bivariate analysis, was seen to be significantly influenced (P<0.05) by the preoperative and intraoperative low radiotracer uptake (axilla/lesion radiotracer uptake ratio<1%), low level of experience of the specialist in nuclear medicine, luminal A subtype, and radiotracer uptake localization in internal mammary lymph nodes. On multivariate analysis, significant risk factors for sentinel node identification failure were found to be: axilla/lesion radiotracer uptake ratio less than 1%, radiotracer uptake localization in internal mammary lymph nodes, and luminal A subtype. Considering only the preoperative variables in our multivariate analysis, axilla/lesion radiotracer uptake ratio less than 1%, negative lymph node scintiscan, and radiotracer uptake localization in internal mammary lymph nodes had an area under the curve (receiver operating characteristic curve) of 96% (95% confidence interval 92-100%). Further, we built a nomogram based on these simple parameters for counseling the patient about the probability of not finding the sentinel lymph node during the surgical procedure. CONCLUSION: The relatively low prevalence of SLNB failure (2%) is indicative of the accuracy of the procedure when performed by experienced surgeons. The sentinel node identification failure in our population seemed to be related to biological tumor factors (luminal A subtype) and probably to physiological or pathological variations in the lymphatic drainage (axilla/lesion radiotracer uptake ratio<1% and radiotracer uptake localization in internal mammary lymph nodes). © 2013 Wolters Kluwer Health | Lippincott Williams & Wilkins.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/1138839
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 17
social impact