This article presents the results of the numerical simulations of a dynamic experimental campaign on the shaking table. The specimen is a full-scale masonry cross vault without and with the textile-reinforced mortar used as a strengthening solution. The specimen was tested in the scope of the European project SERA.ta 07 “Seismic Response of Masonry Cross Vaults: Shaking table tests and numerical validations”. The specimen replicates a generic cross-section of a central bay located in the lateral nave of a three-nave church, where the recurrent in-plane shear mechanism is induced. Finite element model (FEM) and discrete element model (DEM) were built and calibrated based on the experimental frequencies and mode shapes. Then, a unidirectional seismic action was applied to the numerical model in order to develop shear damage in the shell of the vault. A detailed description of the two simulations and their main outcomes are presented. The response was evaluated based on the displacements, damage, collapse mechanisms and hysteretic behaviour.

Modelling of the Dynamic Response of a Full-Scale Masonry Groin Vault: Unstrengthened and Strengthened with Textile-Reinforced Mortar (TRM)

Calderini C.
2024-01-01

Abstract

This article presents the results of the numerical simulations of a dynamic experimental campaign on the shaking table. The specimen is a full-scale masonry cross vault without and with the textile-reinforced mortar used as a strengthening solution. The specimen was tested in the scope of the European project SERA.ta 07 “Seismic Response of Masonry Cross Vaults: Shaking table tests and numerical validations”. The specimen replicates a generic cross-section of a central bay located in the lateral nave of a three-nave church, where the recurrent in-plane shear mechanism is induced. Finite element model (FEM) and discrete element model (DEM) were built and calibrated based on the experimental frequencies and mode shapes. Then, a unidirectional seismic action was applied to the numerical model in order to develop shear damage in the shell of the vault. A detailed description of the two simulations and their main outcomes are presented. The response was evaluated based on the displacements, damage, collapse mechanisms and hysteretic behaviour.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/1179296
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 7
social impact