Purpose: To identify factors that contribute to the speed of angular correction in skeletally immature patients with genu varum treated with paraphyseal tension band plates, hypothesizing that screw length and divergence, severity of deformity, and underlying pathology influence the rate and speed of genu varum correction. Methods: Fifty-three patients (38 males, 15 females) undergoing genu varum correction were included; a total of 138 physes (64 distal femur, 74 proximal tibia) were assessed. The median age at surgery was 37.83 ± 34.27 months (24.37-188.60), and the median follow-up was 11.03 ± 4.9 months (3.17-23). The severity of the deformity, the relative screw length, correction speed (degree per month), and initial screw divergence were calculated for comparison. Results: Patients close to skeletal maturity showed faster correction speed. Patients with genu varum secondary to metabolic disease had the slowest correction speed (0.76° per month), while there was no clinically significant difference with different etiologies. The distal femur showed a lower correction speed than that of proximal tibia in genu varum. The correction rate was negatively correlated with the relative screw length in genu varum deformity (linear regression coefficient: - 2.39; P < 0.01). The initial screw divergence had no statistically significant impact on the correction speed (P = 0.97). Conclusion: Screw length is an important parameter affecting the rate of genu varum correction with GG using paraphyseal tension band plates.

Abstract Purpose To identify factors that contribute to the speed of angular correction in skeletally immature patients with genu varum treated with paraphyseal tension band plates, hypothesizing that screw length and divergence, severity of deformity, and underlying pathology influence the rate and speed of genu varum correction. Methods Fifty-three patients (38 males, 15 females) undergoing genu varum correction were included; a total of 138 physes (64 distal femur, 74 proximal tibia) were assessed. The median age at surgery was 37.83 ± 34.27 months (24.37–188.60), and the median follow-up was 11.03 ± 4.9 months (3.17–23). The severity of the deformity, the relative screw length, correction speed (degree per month), and initial screw divergence were calculated for comparison. Results Patients close to skeletal maturity showed faster correction speed. Patients with genu varum secondary to metabolic disease had the slowest correction speed (0.76° per month), while there was no clinically significant difference with different etiologies. The distal femur showed a lower correction speed than that of proximal tibia in genu varum. The correction rate was negatively correlated with the relative screw length in genu varum deformity (linear regression coefficient: − 2.39; P < 0.01). The initial screw divergence had no statistically significant impact on the correction speed (P = 0.97). Conclusion Screw length is an important parameter affecting the rate of genu varum correction with GG using paraphyseal tension band plates. Level of evidence: IV.

Is there a negative correlation between screw length and correction rate via guided growth? A retrospective study of 138 limbs with genu varum

Canavese, Federico
2025-01-01

Abstract

Abstract Purpose To identify factors that contribute to the speed of angular correction in skeletally immature patients with genu varum treated with paraphyseal tension band plates, hypothesizing that screw length and divergence, severity of deformity, and underlying pathology influence the rate and speed of genu varum correction. Methods Fifty-three patients (38 males, 15 females) undergoing genu varum correction were included; a total of 138 physes (64 distal femur, 74 proximal tibia) were assessed. The median age at surgery was 37.83 ± 34.27 months (24.37–188.60), and the median follow-up was 11.03 ± 4.9 months (3.17–23). The severity of the deformity, the relative screw length, correction speed (degree per month), and initial screw divergence were calculated for comparison. Results Patients close to skeletal maturity showed faster correction speed. Patients with genu varum secondary to metabolic disease had the slowest correction speed (0.76° per month), while there was no clinically significant difference with different etiologies. The distal femur showed a lower correction speed than that of proximal tibia in genu varum. The correction rate was negatively correlated with the relative screw length in genu varum deformity (linear regression coefficient: − 2.39; P < 0.01). The initial screw divergence had no statistically significant impact on the correction speed (P = 0.97). Conclusion Screw length is an important parameter affecting the rate of genu varum correction with GG using paraphyseal tension band plates. Level of evidence: IV.
2025
Purpose: To identify factors that contribute to the speed of angular correction in skeletally immature patients with genu varum treated with paraphyseal tension band plates, hypothesizing that screw length and divergence, severity of deformity, and underlying pathology influence the rate and speed of genu varum correction. Methods: Fifty-three patients (38 males, 15 females) undergoing genu varum correction were included; a total of 138 physes (64 distal femur, 74 proximal tibia) were assessed. The median age at surgery was 37.83 ± 34.27&nbsp;months (24.37-188.60), and the median follow-up was 11.03 ± 4.9&nbsp;months (3.17-23). The severity of the deformity, the relative screw length, correction speed (degree per month), and initial screw divergence were calculated for comparison. Results: Patients close to skeletal maturity showed faster correction speed. Patients with genu varum secondary to metabolic disease had the slowest correction speed (0.76° per month), while there was no clinically significant difference with different etiologies. The distal femur showed a lower correction speed than that of proximal tibia in genu varum. The correction rate was negatively correlated with the relative screw length in genu varum deformity (linear regression coefficient: - 2.39; P &lt; 0.01). The initial screw divergence had no statistically significant impact on the correction speed (P = 0.97). Conclusion: Screw length is an important parameter affecting the rate of genu varum correction with GG using paraphyseal tension band plates.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/1262739
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact