One of the ways to decarbonize cities and to enhance grid stability is to convert existing buildings into prosumers equipped with power plants able to supply electrical and thermal energy. The simulation of such multi-energy systems permits the analysis of their performance in steady-state and dynamic conditions, with the aim of defining effective operating strategies able to reduce emissions and costs. The present paper describes a dynamic simulation model, implemented in the Matlab/Simulink R2025a environment, developed to simulate the daily and weekly operation of a prosumer building equipped with a small-sized cogeneration unit, a Photovoltaic (PV) plant, a back-up boiler, a thermal storage system and some charging points for Electric Vehicles (EVs). The mathematical model is reported in detail, and the main results of the study are described, referring to operating days characterized by different weather conditions. Then, energy, economic and environmental performance indicators are defined and calculated for the different simulated scenarios. Over the considered time horizons, the simulation results highlight a significant increase in the electrical self-sufficiency of the facility up to 91.1% and an important reduction in total net operating costs up to 59.8%, compared to the AS-IS case (i.e., without the newly installed technologies).

Dynamic Simulation Model of a Prosumer Building with PV, CHP, Thermal Storage and Electric Vehicle Charging Points

Stefano Bracco;Matteo Fresia;Tommaso Robbiano;Federico Silvestro;Stefano Massucco
2026-01-01

Abstract

One of the ways to decarbonize cities and to enhance grid stability is to convert existing buildings into prosumers equipped with power plants able to supply electrical and thermal energy. The simulation of such multi-energy systems permits the analysis of their performance in steady-state and dynamic conditions, with the aim of defining effective operating strategies able to reduce emissions and costs. The present paper describes a dynamic simulation model, implemented in the Matlab/Simulink R2025a environment, developed to simulate the daily and weekly operation of a prosumer building equipped with a small-sized cogeneration unit, a Photovoltaic (PV) plant, a back-up boiler, a thermal storage system and some charging points for Electric Vehicles (EVs). The mathematical model is reported in detail, and the main results of the study are described, referring to operating days characterized by different weather conditions. Then, energy, economic and environmental performance indicators are defined and calculated for the different simulated scenarios. Over the considered time horizons, the simulation results highlight a significant increase in the electrical self-sufficiency of the facility up to 91.1% and an important reduction in total net operating costs up to 59.8%, compared to the AS-IS case (i.e., without the newly installed technologies).
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/1297337
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact