Highlights Modelling provides requirements for impedance reconstruction via current interruption A Gaussian window must be introduced in Fourier transform to damp measurement noise Sampling at 70 μs for 40 s enables reconstruction at 1% accuracy within 10−1-103 Hz The technique may be integrated for on-line state-of-health evaluation of batteries

Requirements for Applying the Current Interruption Technique for Reconstructing the Impedance of Li-Ion Batteries

Maria Paola Carpanese;
2025-01-01

Abstract

Highlights Modelling provides requirements for impedance reconstruction via current interruption A Gaussian window must be introduced in Fourier transform to damp measurement noise Sampling at 70 μs for 40 s enables reconstruction at 1% accuracy within 10−1-103 Hz The technique may be integrated for on-line state-of-health evaluation of batteries
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11567/1308938
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact